Only one of the new US companies has come back to me, and they wanted to charge me $6 each for 25 sample magnets, plus shipping. I suggested they send just two to me in Florida next month. So then these two totalled the same as the 25, two at $65 each. I said goodbye. Perhaps they don't understand the "loss leader" principle.
Actually, this is typically Chinese thinking from my experience. Send a few samples at extortionate cost to make some money as you know you can't supply what the customer really wants.
Meanwhile, I've incorporated my low-friction idea into new magnets installed into the lower stack of the Jupiter prototype and it removes the "Squeeze leak" issue same as the original sample magnets did, same as the short lived PTFE coated magnets did, if you remember that:
My introducing low-friction material into the mix I hope to have eradicated the wear issue that my severe tests were all about. In reality just four magnets (lower stack, see below) have to survive the odd occasion where gorilla grip is in use but of course I still have to worry about the occasional player who uses this "technique" constantly. I haven't given up on bettering the magnet coating as produced though, and am discussing this with the original US supplier (very patient and helpful they are too).
Having re-adjusted and regulated the whole sax it seems this issue only affects the lower stack keys whereas you'd expect the upper stack to be similarly prone to gorilla grip, but it doesn't seem to be. Part of the reason may be the smaller pads and shorter length of the "lever", i.e. the distance from pad edge to centre. Using a leak light I can't squeeze the upper stack hard enough to leave a leak upon next soft close of the same pads, per the squeeze leak test.
So I'll leave the Jupiter alone other than new magnets in the lower stack, retaining the original "rough" magnets elsewhere, just to see how they fare.
However the YAS-21 I had wet soda blasted (remember?) will now have a full new set of 22 low-friction magnets installed. It also has reflector-less pads going in. That is, they have no reflector, just the smooth bare face of the stainless steel backing disc surrounded by a ring of sealing material.
Here's a thing... if the magnet was too low-friction OR too powerful, or both, the pads, certainly the smaller ones, would have a tendency to self-centre not to the tone hole but to the magnet. That's because the plated steel screw, which sits into the magnet's countersink, has more steel mass in its thread than in its button head. The ring magnet would act more powerfully on the screw's core thread and pull it upright, perpendicular to the magnet's plane.
It takes a careful balance of pull strength and countersink friction (mostly by trial and error) to allow any sized pad to be able to self-level to the tone hole rim and then stay static and hold that position when the pad opens and closes continuously thereafter. I noticed in my tests that Jim Schmidt's self-levelling pad, once the ball and socket is loosened after a few removals and replacements, just flops around and so has to waste milliseconds finding its level again on every actuation. I wonder if Music Medic's new Neo pad will suffer the same floppiness, having as it does the same ball and socket arrangement (a collaboration with Jim).
I'm pleased to say mine has never been floppy and always holds firm in play.
Talking of play... this project is just that. It's not my life's ambition to invent something or to make a living out of its success. It's purely having an idea, a theory, and then trying to see it work in practice.
It does, but will it stand up to another round of trials by players and techs?
The first trials lasted just two players before the squeeze leak was found.
Better luck next time? We'll see...