Tech/maintenance My new "DIY" pads...

Just (hand) cut and glued a set of tenor pads, ready for assembly with MM reflectors...

20230312_185614.webp


...awaiting new custom magnets from the US any day now to complete the installation. These pads are for another prototype sax for testing, but not one of mine.
 
Update...

The sample magnets from a US supplier were good, extreme testing found the special coating to be smooth and durable. A first production batch was ordered.

These arrived end March and were no good, they failed less intensive durability tests. It turns out a different application process was used for the coating. The supplier said their factory would redo them FOC to the original specification of the samples.

The 2nd production batch (replacements) arrived today. They are no good, failing wear tests again.
I've chastised the supplier for sending great samples which they do not seem to be able to match in production. I await their reply.

They have to be right...
 
Yes, when I emailed them today I did say...

"...It is worrying, don't you think, that a finish you may be supplying on your products to existing customers cannot be replicated when they re-order the same product once again."

I tried a dozen or so Chinese factories direct but it seemed the language barrier was too great, or they wanted to flog me a different, unsuitable, product. Although I can speak easily with the current US suppier, their factory is... in China, so maybe they have similar communication issues?
 
No, but they are the factory's "top customer." :rolleyes:
It seems China is the only place to get these made nowadays, but finding a Chinese factory which can cope is impossible.

My good UK friend, chairman of a Chinese company with a (machine tool) factory there had one of his Chinese staff assess a number of likely prospects by reputation, size, capacity, customer satisfaction, etc.

I tried those kindly recommended but still I can't get what I want. Perhaps I'm looking for the impossible... only I'm not because I have what I want in the USA/China samples, albeit the wrong thickness hence the custom order.
 
@DavidUK

If you can’t find something here I would source Japan.


The two sources listed in Califonia are a hour away from my house.
:20 apart from each other.
Let me know if you need assistance. I’ll do what can.
 
@PigSquealer - thanks, I've emailed some of them just now.

Meanwhile... today I experimented some more to create a miniature low-friction insert to the countersunk area. This worked well but I need to do some more testing. I'm not sure it's a permanent solution as it's currently a bit Heath Robinson.

But... if you can't find someone to make it, create it yourself! :thumb:
 
Only one of the new US companies has come back to me, and they wanted to charge me $6 each for 25 sample magnets, plus shipping. I suggested they send just two to me in Florida next month. So then these two totalled the same as the 25, two at $65 each. I said goodbye. Perhaps they don't understand the "loss leader" principle.
Actually, this is typically Chinese thinking from my experience. Send a few samples at extortionate cost to make some money as you know you can't supply what the customer really wants.

Meanwhile, I've incorporated my low-friction idea into new magnets installed into the lower stack of the Jupiter prototype and it removes the "Squeeze leak" issue same as the original sample magnets did, same as the short lived PTFE coated magnets did, if you remember that:

My introducing low-friction material into the mix I hope to have eradicated the wear issue that my severe tests were all about. In reality just four magnets (lower stack, see below) have to survive the odd occasion where gorilla grip is in use but of course I still have to worry about the occasional player who uses this "technique" constantly. I haven't given up on bettering the magnet coating as produced though, and am discussing this with the original US supplier (very patient and helpful they are too).

Having re-adjusted and regulated the whole sax it seems this issue only affects the lower stack keys whereas you'd expect the upper stack to be similarly prone to gorilla grip, but it doesn't seem to be. Part of the reason may be the smaller pads and shorter length of the "lever", i.e. the distance from pad edge to centre. Using a leak light I can't squeeze the upper stack hard enough to leave a leak upon next soft close of the same pads, per the squeeze leak test.

So I'll leave the Jupiter alone other than new magnets in the lower stack, retaining the original "rough" magnets elsewhere, just to see how they fare.

However the YAS-21 I had wet soda blasted (remember?) will now have a full new set of 22 low-friction magnets installed. It also has reflector-less pads going in. That is, they have no reflector, just the smooth bare face of the stainless steel backing disc surrounded by a ring of sealing material.

Here's a thing... if the magnet was too low-friction OR too powerful, or both, the pads, certainly the smaller ones, would have a tendency to self-centre not to the tone hole but to the magnet. That's because the plated steel screw, which sits into the magnet's countersink, has more steel mass in its thread than in its button head. The ring magnet would act more powerfully on the screw's core thread and pull it upright, perpendicular to the magnet's plane.

It takes a careful balance of pull strength and countersink friction (mostly by trial and error) to allow any sized pad to be able to self-level to the tone hole rim and then stay static and hold that position when the pad opens and closes continuously thereafter. I noticed in my tests that Jim Schmidt's self-levelling pad, once the ball and socket is loosened after a few removals and replacements, just flops around and so has to waste milliseconds finding its level again on every actuation. I wonder if Music Medic's new Neo pad will suffer the same floppiness, having as it does the same ball and socket arrangement (a collaboration with Jim).

I'm pleased to say mine has never been floppy and always holds firm in play.

Talking of play... this project is just that. It's not my life's ambition to invent something or to make a living out of its success. It's purely having an idea, a theory, and then trying to see it work in practice.
It does, but will it stand up to another round of trials by players and techs?
The first trials lasted just two players before the squeeze leak was found.

Better luck next time? We'll see...
 
Only one of the new US companies has come back to me, and they wanted to charge me $6 each for 25 sample magnets, plus shipping. I suggested they send just two to me in Florida next month. So then these two totalled the same as the 25, two at $65 each. I said goodbye. Perhaps they don't understand the "loss leader" principle.
Actually, this is typically Chinese thinking from my experience. Send a few samples at extortionate cost to make some money as you know you can't supply what the customer really wants.

Meanwhile, I've incorporated my low-friction idea into new magnets installed into the lower stack of the Jupiter prototype and it removes the "Squeeze leak" issue same as the original sample magnets did, same as the short lived PTFE coated magnets did, if you remember that:

My introducing low-friction material into the mix I hope to have eradicated the wear issue that my severe tests were all about. In reality just four magnets (lower stack, see below) have to survive the odd occasion where gorilla grip is in use but of course I still have to worry about the occasional player who uses this "technique" constantly. I haven't given up on bettering the magnet coating as produced though, and am discussing this with the original US supplier (very patient and helpful they are too).

Having re-adjusted and regulated the whole sax it seems this issue only affects the lower stack keys whereas you'd expect the upper stack to be similarly prone to gorilla grip, but it doesn't seem to be. Part of the reason may be the smaller pads and shorter length of the "lever", i.e. the distance from pad edge to centre. Using a leak light I can't squeeze the upper stack hard enough to leave a leak upon next soft close of the same pads, per the squeeze leak test.

So I'll leave the Jupiter alone other than new magnets in the lower stack, retaining the original "rough" magnets elsewhere, just to see how they fare.

However the YAS-21 I had wet soda blasted (remember?) will now have a full new set of 22 low-friction magnets installed. It also has reflector-less pads going in. That is, they have no reflector, just the smooth bare face of the stainless steel backing disc surrounded by a ring of sealing material.

Here's a thing... if the magnet was too low-friction OR too powerful, or both, the pads, certainly the smaller ones, would have a tendency to self-centre not to the tone hole but to the magnet. That's because the plated steel screw, which sits into the magnet's countersink, has more steel mass in its thread than in its button head. The ring magnet would act more powerfully on the screw's core thread and pull it upright, perpendicular to the magnet's plane.

It takes a careful balance of pull strength and countersink friction (mostly by trial and error) to allow any sized pad to be able to self-level to the tone hole rim and then stay static and hold that position when the pad opens and closes continuously thereafter. I noticed in my tests that Jim Schmidt's self-levelling pad, once the ball and socket is loosened after a few removals and replacements, just flops around and so has to waste milliseconds finding its level again on every actuation. I wonder if Music Medic's new Neo pad will suffer the same floppiness, having as it does the same ball and socket arrangement (a collaboration with Jim).

I'm pleased to say mine has never been floppy and always holds firm in play.

Talking of play... this project is just that. It's not my life's ambition to invent something or to make a living out of its success. It's purely having an idea, a theory, and then trying to see it work in practice.
It does, but will it stand up to another round of trials by players and techs?
The first trials lasted just two players before the squeeze leak was found.

Better luck next time? We'll see...
yours has never been floppy and holds firm in play...lucky you...saves a trip to chemist...lol.
 
Update, six months on...

In brief...
  • two altos out for testing last 3-4 months with techs and players. Feedback?:
  • bell key pads dropped out of position in transit. Easily replaced (push back in) but not ideal.
  • pad material too soft for 'feel' (compared to traditional pads).
  • revised the pad sealing material - slightly firmer lower stack set sent to one tester for DIY replacment.
  • tester replaced pads OK (removed, dismantled, reassembled, replaced - doesn't take long).
  • replaced lower stack feels better per tester
  • firmer material tested for compression recovery. Takes 48hrs but returns to original smoothness.
  • revised the magnet design for larger pads, 40mm and above, with anti-dropout lip.
  • revised standard magnets with new harder wearing smooth finish
  • both new magnet types order arrived but to incorrect spec after 2 1/2 months
  • threw hissy fit and almost gave up on the idea!
  • magnets re-made, arrived this week.
  • prototype tenor (Beaugnier) fitted with new pads and new anti-dropout bell key magnets (B; Bb) to test in transit.
  • other five pads over 40mm left with original magnets to see if they too drop out of a tenor in transit. If so, the anti-dropout pads will be fitted to these five cups on a tenor, seven total on this one.
  • Tested new glue for magnets - Gorilla Superglue. Fails to glue magnets to cups. Back to Loctite Extreme.
  • tenor to be reassembled (had to re-do the magnets with Loctite) and then sent to tech for set up, in transit dropout test, playability, then on to field testers
  • Next: More feedback expected on tenor over coming weeks/months. Revise two alto prototypes with new material and new magnets. Re-send these prototypes out for more field testing.
 
I very much admire your commitment to this project.

firmer material tested for compression recovery. Takes 48hrs but returns to original smoothness.

So that is kind of good news and bad news. Unless it still forms a good seal during that 48 hours. However I guess that is not going to be an issue with the anti dropout pads, and presumably they do not rate while in place on the horn (otherwise off-center tone hole indents could be problematic.
 
As the pad is almost aways non-concentric to the tone hole the theoretical issue, as stated before, is that if a pad rotates in use a new seat may form on sprung closed keys which crosses an old seat and a leak may occur at the intersections of the two seats.

In practice the new seat will be compressed very quickly to the depth of the old seat and so at the point where they cross the compressed sealing material is at the same level, old and new, so no noticeable leak should happen.

The pads generally only rotate when removed and replaced in a different orientation. In situ the magnets are strong enough to prevent rotation, however I sought to over engineer the sealing material to cater for an ad hoc rotation by finding a 'self-healing' neoprene which would recover to flat. I recall you had such an issue Pete when querying a seat on one of the prototype altos with the softer material. I said "wait 24hrs' and you later confirmed the seat had disappeared. The firmer material just tales a little longer as it's a little less spongey.

The anti-dropout magnets stop the pad's screw head sliding sideways out of the magnet's countersink. This is how they escape. They do not come out easily perpendicular to the magnet's face. The anti-dropout magnets are also larger in diameter and 0.5mm thicker which increases their pull force to ensure the pads stay put. They may even be a tad too wide, having a tendency to pull a bare pad screw (no pad attached) to one side if provoked that way but my tests on the tenor show the extra mass of the pad and the slight angle from perpendicular needed to match a tone hole's face stop this fall over effect. Field testing will show if I need to amend further these magnets' diameter or strength.

The firmer material hopefully solves the 'feel' issue. I tried the tenor (with dodgy magnets, now replaced) side by side with the Jupiter alto. The firmer tenor material 'feels' more like leather pads and produces a similar pop during the 'pop test'. The softer alto material still feels fine, but 'different' to what folks are used to.
Different isn't good when trying to sway players' opinion as to the effectiveness a new product.
 
It's a long thread and have not managed to read all of it so sorry if all this has been said before. Poor old Adolph was reviled, blown up attacked ( according to a biography). If that had stopped him, no saxophones. Many mods to materials/keywork have happened since then. Hope this works for David. Keep trying!

(hve managed t) changed to (have not managed to). Proof reading not working today.
 
Last edited:

Social

New! Social Feeds

Look out for the navigation icon:

Follow CafeSaxophone

Latest Song of the Month

Trending

Forum statistics

Topics
32,080
Messages
578,785
Members
8,137
Latest member
AdrianoHoma
Back
Top Bottom